Smart Electric Meters
Our smart electric meters are more than just allications; they're your partners in energy efficiency. By providing real-time data on your electricity consumption, you gain unprecedented control over your energy usage.
Know about Smart Electric Meters
Real-time energy monitoring: Track your electricity consumption in detail, hour by hour. Cost savings: Identify energy-intensive habits and make informed decisions to reduce your bills. Environmental impact: Contribute to a greener planet by optimizing energy use. Remote control: Manage your energy consumption from anywhere with our user-friendly app. Enhanced grid reliability: Support a more stable and efficient electricity grid. Experience the future of energy management with our smart electric applications. Contact us today to learn more!
40+ years
Success in the market
1 Million Electric Meter
Manufactured by SMC Saudi Arabia
Smart Electric Meter
Smart electric meters are equipped with sensors and communication capabilities that enable automated data collection and transmission.
- Empower Utilities
- Reduce Electricity Loss
- Energy Efficiency
Features
Measurement and power quality
Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power.
configurable maximum demand integration period (typically 5,15,30 or 60 minutes
instantaneous import voltage and current per phase, import export power factor, frequency instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
Communication interface
Optical port, Baud rate default 9600bps, Plug and play module,one RS- 485 interface for external communication
Multi-Tarrif
Two sets of tariff structure, up to four tariffs, 4 season/week/day profiles,200 special days
Disconnect and Reconnect
A latching relay which complies with IEC 62055-31 UC3, UC3, supports the disconnect and reconnect power supply.
Application
Enhance the Information & Interaction between the Utility and the Consumers
Types of Electric Meters
MA309MH4LSA1 Smart Three Phase Application with Direct Connection
- Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
- Compliant with DLMS/COSEM
- Energy efficiency with advanced measurement with TOU
- Auxiliary relay output control and ECB RS-485 communication
- Remote authenticated firmware upgrade
- Protect from fraud or tamper
- Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power, configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes)
- Instantaneous import voltage and current per phase, import/export power factor, Frequency, Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase
- 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
- 3 monthly billing data, 3 daily billing data
- At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
- At least 90 days capacity for a 30 minutes period
- Remote and local synchronization available
- Optical port
- Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
- Two RS-485 ports, one for external module/RS-485 smart application/ECB, another for IHD
- Character type LCD to support text-based messages with backlight
- Two LEDs indicate active and reactive pulse
- One bi-color LED indicates the remote communication status
- Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
- Replaceable battery with independent seal, support at least 1 year without main power supply
- Current reversal detection and measurement, Magnetic detection and protection, Face and terminal cover open detection, neutral line missing, Phase-neutral swap and other self-diagnostic functions, Ultrasonic wielding application cover, one-direction metrological screws
- Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
• 250V/1A auxiliary relay
MA309MT3LSA Smart Three Phase Application with CTVT Connection
- Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
- Compliant with DLMS/COSEM
- Energy efficiency with advanced measurement with TOU
- Auxiliary relay output control and ECB RS-485 communication
- kWh, kVarh and EOI pulse, I/O and auxiliary power supply terminals
- Remote authenticated firmware upgrade
- Protect from fraud or tamper
- Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes), Instantaneous voltage and current per phase, import power factor, Frequency, Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase
- 2 sets of tariff structure, up to 8 tariffs, 8 season/week/day profiles, 420 special days
- 3 monthly billing data, 3 daily billing data
- At least 12 programmable channels for energy and demand load profile, At least 16 programmable channels for power quality load profile, Programmable profiles period (typically 5, 15, 30, 60 minutes)
- At least 90 days capacity for a 30 minutes period
- Remote and local synchronization available
- Optical port
- Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
- Two RS-485 ports, one for external module/RS-485 smart application/ECB, another for IHD
- Terminals for kWh, kVarh and EOI pulse and four I/O
- Character type LCD to support text based messages with back light
- Two LEDs indicate active and reactive pulse
- One bi-color LED indicates the remote communication status
- Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
- Replaceable battery with independent seal, support at least 1 years without main power supply
- Current reversal detection and measurement, Magnetic detection and protection, Face and terminal cover open detection, Neutral line missing, CT open, CT bypass and other self-diagnostic functions
- Ultrasonic wielding application cover, one-direction metrological screws
- Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
- 250V/1A auxiliary relay
- kWh, kVarh and EOI pulse terminals
- Four I/O terminals & Auxiliary power supply (230VAC or 125VDC) (Optional)
MA309MH4LSA Smart Three Phase application with Direct Connection
- Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
- Compliant with DLMS/COSEM
- Energy efficiency with advanced measurement with TOU
- Internal disconnect /reconnect output control
- Remote authenticated firmware upgrade
- Protect from fraud and tamper
- Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes); Instantaneous import voltage and current per phase, import/export power factor, Frequency; Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
- 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
- 3 monthly billing data, 3 daily billing data
- At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
- At least 90 days capacity for a 30 minutes period.
- Remote and local synchronization available
- Optical port
- Plug-and-Play module with PRIME-PLC/G-PLC/4G-LTE/NB-IoT (with GPS) technology
- Two RS-485 ports, one for external module/RS-485 smart application; another for IHD
- Character type LCD to support text-based messages with backlight
- Two LEDs indicate active and reactive pulse
- One bi-color LED indicates the remote communication status
- A latching relay, which complies with IEC 62055-31 UC3, supports dis/reconnect output control.
- Replaceable battery with independent seal, support at least 1 year without main power supply
- Current reversal detection and measurement; Magnetic detection and protection; Face and terminal cover open detection; neutral line missing; Phase-neutral swap and other self-diagnostic functions
- Ultrasonic wielding application cover, one-direction metrological screws
- Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
MA309MT4LSA Smart Three Phase Application with CT Connection
- Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
- Compliant with DLMS/COSEM
- Energy efficiency with advanced measurement with TOU
- Auxiliary relay output control and ECB RS-485 communication
- kWh, kVarh and EOI pulse terminal
- Remote authenticated firmware upgrade
- Protect from fraud or tamper
- Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes); Instantaneous voltage and current per phase, import power factor, Frequency; Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
- 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
- 3 monthly billing data, 3 daily billing data
- At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
- At least 90 days capacity for 30 minutes period.
- Remote and local synchronization available
- Optical port
- Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
- Two RS-485 ports, one for external module/RS-485 smart application/ECB; another for IHD
- Three pulse terminals for kWh, kVarh and EOI
- Character type LCD to support text based messages with back light
- Two LEDs indicate active and reactive pulse
- One bi-color LED indicates the remote communication status
- Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
- Replaceable battery with independent seal, support at least 1 years without main power supply
- Current reversal detection and measurement; Magnetic detection and protection; Face and terminal cover open detection, Neutral line missing; CT open; CT bypass and other self-diagnostic functions
- Ultrasonic wielding application cover, one-direction metrological screws
- Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
- 250V/1A auxiliary relay
- kWh, kVarh and EOI pulse terminals
- IEC 62052-11, IEC 62053-21/22, EN 50470-1/3, DIN 43857, IEC 62056-21/46/53/61/62 Accuracy Active Class 0.5S Reactive Class 2.0 Voltage CT Rated voltage 3x230V/400V, 3x133V/230V Operation voltage range 80% to 120% Un Current Rated current 1.5 (6) A Starting current 1.5mA Frequency 50/60Hz ± 5% Hz Pulse constant 10000 imp/kWh(kVarh) (configurable as requirement) Application life ≥ 15 Years D