Smart Electric
Application
Our smart electric applications are more than just allications; they’re your partners in energy efficiency. By providing real-time data on your electricity consumption, you gain unprecedented control over your energy usage.
Real-time energy monitoring: Track your electricity consumption in detail, hour by hour. Cost savings: Identify energy-intensive habits and make informed decisions to reduce your bills. Environmental impact: Contribute to a greener planet by optimizing energy use. Remote control: Manage your energy consumption from anywhere with our user-friendly app. Enhanced grid reliability: Support a more stable and efficient electricity grid. Experience the future of energy management with our smart electric applications. Contact us today to learn more!
By leveraging technology, smart water applications are empowering both consumers and utilities to make informed decisions about water usage and conservation. These smart applications play a crucial role in ensuring sustainable water management practices.
Success in the market
Hydrus smart application supplied in ksa network
Manufactured by SMC Saudi Arabia
Smart electric applications are equipped with sensors and communication capabilities that enable automated data collection and transmission.
Enhance the Information & Interaction between the Utility and the Consumers
Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
• Compliant with DLMS/COSEM
• Energy efficiency with advanced measurement with TOU
• Auxiliary relay output control and ECB RS-485 communication
• Remote authenticated firmware upgrade
• Protect from fraud or tamper
• Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power, configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes)
• Instantaneous import voltage and current per phase, import/export power factor, Frequency, Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase
• 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
• 3 monthly billing data, 3 daily billing data
• At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
• At least 90 days capacity for a 30 minutes period
• Remote and local synchronization available
• Optical port
• Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
• Two RS-485 ports, one for external module/RS-485 smart application/ECB, another for IHD
• Character type LCD to support text-based messages with backlight
• Two LEDs indicate active and reactive pulse
• One bi-color LED indicates the remote communication status
• Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
• Replaceable battery with independent seal, support at least 1 year without main power supply
• Current reversal detection and measurement, Magnetic detection and protection, Face and terminal cover open detection, neutral line missing, Phase-neutral swap and other self-diagnostic functions, Ultrasonic wielding application cover, one-direction metrological screws
• Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
• 250V/1A auxiliary relay
• Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
• Compliant with DLMS/COSEM
• Energy efficiency with advanced measurement with TOU
• Auxiliary relay output control and ECB RS-485 communication
• kWh, kVarh and EOI pulse, I/O and auxiliary power supply terminals
• Remote authenticated firmware upgrade
• Protect from fraud or tamper
• Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes), Instantaneous voltage and current per phase, import power factor, Frequency, Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase
• 2 sets of tariff structure, up to 8 tariffs, 8 season/week/day profiles, 420 special days
• 3 monthly billing data, 3 daily billing data
• At least 12 programmable channels for energy and demand load profile, At least 16 programmable channels for power quality load profile, Programmable profiles period (typically 5, 15, 30, 60 minutes)
• At least 90 days capacity for a 30 minutes period
• Remote and local synchronization available
• Optical port
• Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
• Two RS-485 ports, one for external module/RS-485 smart application/ECB, another for IHD
• Terminals for kWh, kVarh and EOI pulse and four I/O
• Character type LCD to support text based messages with back light
• Two LEDs indicate active and reactive pulse
• One bi-color LED indicates the remote communication status
• Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
• Replaceable battery with independent seal, support at least 1 years without main power supply
• Current reversal detection and measurement, Magnetic detection and protection, Face and terminal cover open detection, Neutral line missing, CT open, CT bypass and other self-diagnostic functions
• Ultrasonic wielding application cover, one-direction metrological screws
• Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
• 250V/1A auxiliary relay
• kWh, kVarh and EOI pulse terminals
• Four I/O terminals & Auxiliary power supply (230VAC or 125VDC) (Optional)
• Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
• Compliant with DLMS/COSEM
• Energy efficiency with advanced measurement with TOU
• Internal disconnect /reconnect output control
• Remote authenticated firmware upgrade
• Protect from fraud and tamper
• Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes); Instantaneous import voltage and current per phase, import/export power factor, Frequency; Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
• 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
• 3 monthly billing data, 3 daily billing data
• At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
• At least 90 days capacity for a 30 minutes period.
• Remote and local synchronization available
• Optical port
• Plug-and-Play module with PRIME-PLC/G-PLC/4G-LTE/NB-IoT (with GPS) technology
• Two RS-485 ports, one for external module/RS-485 smart application; another for IHD
• Character type LCD to support text-based messages with backlight
• Two LEDs indicate active and reactive pulse
• One bi-color LED indicates the remote communication status
• A latching relay, which complies with IEC 62055-31 UC3, supports dis/reconnect output control.
• Replaceable battery with independent seal, support at least 1 year without main power supply
• Current reversal detection and measurement; Magnetic detection and protection; Face and terminal cover open detection; neutral line missing; Phase-neutral swap and other self-diagnostic functions
• Ultrasonic wielding application cover, one-direction metrological screws
• Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
• Plug and play communication module which supports PRIME-PLC/G3-PLC/4G-LTE/ NB-IoT (with GPS) technology
• Compliant with DLMS/COSEM
• Energy efficiency with advanced measurement with TOU
• Auxiliary relay output control and ECB RS-485 communication
• kWh, kVarh and EOI pulse terminal
• Remote authenticated firmware upgrade
• Protect from fraud or tamper
• Import and export active/reactive/apparent energy/demand/power, 4 quadrants reactive energy/power; Configurable maximum demand integration period (typically 5, 15, 30 or 60 minutes); Instantaneous voltage and current per phase, import power factor, Frequency; Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
• 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
• 3 monthly billing data, 3 daily billing data
• At least 12 programmable channels for energy and demand load profile; At least 16 programmable channels for power quality load profile; Programmable profiles period (typically 5, 15, 30, 60 minutes)
• At least 90 days capacity for 30 minutes period.
• Remote and local synchronization available
• Optical port
• Plug-and-Play module with PRIME-PLC/G3-PLC/4G-LTE/NB-IoT (with GPS) technology
• Two RS-485 ports, one for external module/RS-485 smart application/ECB; another for IHD
• Three pulse terminals for kWh, kVarh and EOI
• Character type LCD to support text based messages with back light
• Two LEDs indicate active and reactive pulse
• One bi-color LED indicates the remote communication status
• Supports dis/reconnect ECB output control, ECB status check, ECB tamper detection and ECB upgrade
• Replaceable battery with independent seal, support at least 1 years without main power supply
• Current reversal detection and measurement; Magnetic detection and protection; Face and terminal cover open detection, Neutral line missing; CT open; CT bypass and other self-diagnostic functions
• Ultrasonic wielding application cover, one-direction metrological screws
• Two RJ-45 terminals for two RS-485 ports with 12VDC 5W output; IHD supported (one port)
• 250V/1A auxiliary relay
• kWh, kVarh and EOI pulse terminals
• IEC 62052-11, IEC 62053-21/22, EN 50470-1/3, DIN 43857, IEC 62056-21/46/53/61/62 Accuracy Active Class 0.5S Reactive Class 2.0 Voltage CT Rated voltage 3x230V/400V, 3x133V/230V Operation voltage range 80% to 120% Un Current Rated current 1.5 (6) A Starting current 1.5mA Frequency 50/60Hz ± 5% Hz Pulse constant 10000 imp/kWh(kVarh) (configurable as requirement) Application life ≥ 15 Years D